Your Address : Globalchemmade--Arun Diagnostics Systems
Name:Arun Diagnostics Systems
Type:Others
Tel:+(91)-(422)-657967
Fax:
Email:info@Arun.com
Address:China(Mainland)
Equipents offer detail
Equipment: | Automated Hematology Analyzer | |
Equipment Type: | Assembly Equipment -> Comminutor | |
Unit Type: | ||
Place Of Origin: | ||
Price: | Inquire | |
Valid Period: | ||
Technical Parameters: | ||
Usage: | ||
Main Features: | Automated Hematology Analyzer We offer an exclusive range of automated hematology analyzer which is highly appreciated across the medical industry. Procured from trusted manufacturers our range is widely appreciated for easy usage, maintenance and long working life. XT-2000i XT-180CK Parameters WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, NEUT%, LYMPH%, MONO%, E0%, BASO%, NEUT#, LYMPH#, MONO#, EO#, BASO#, RET%, RET#, RDW-SD, RDW-CV, PDW*, MPV, PCT*, P-LCR*, HFR*, MFR*, LFR*, IRF, WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, NEUT%, LYMPH%, MONO%, EO%, BASO%, NEUT#, LYMPH#, MONO#, EO#, BASO#, RDW-SD, RDW-CV, PDW*, MPV, PCT P-LCR* Research Parameters %. IG# Detection Principles Flow cytometry method using a semiconductor laser (WBC, WBC5DIFF, RET) Hydrodynamic focusing DC detection method (RBC, PLT) SLS-hemoglobin method (HGB) Flow cytometry method using a semiconductor laser (WBC, WBC5DIFF) Hydrodynamic focusing DC detection method (RBC, PLT) SLS-hemoglobin method (HGB) Throughput Up to 80 samples/hour Discrete Testing CBC Mode, CBC + DIFF Mode CBC+DIFF+RETMode CBC+RET Mode CBC Mode, CBC+DIFF Mode Sample Volume Manual Mode : 85 microlitre Manual Closed Mode : 150 microlitre Capillary Mode : 40 microlitre Data Storage Analysis data : Up to 10,000 with histograms and scatter grams Patient Information : Up to 5,000 patients Test Order Information : Up to 1,000 orders Quality Control Files: 21 files, each with 300 data points. | |
Description: | Automated Hematology Analyzer We offer an exclusive range of automated hematology analyzer which is highly appreciated across the medical industry. Procured from trusted manufacturers our range is widely appreciated for easy usage, maintenance and long working life. XT-2000i XT-180CK Parameters WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, NEUT%, LYMPH%, MONO%, E0%, BASO%, NEUT#, LYMPH#, MONO#, EO#, BASO#, RET%, RET#, RDW-SD, RDW-CV, PDW*, MPV, PCT*, P-LCR*, HFR*, MFR*, LFR*, IRF, WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, NEUT%, LYMPH%, MONO%, EO%, BASO%, NEUT#, LYMPH#, MONO#, EO#, BASO#, RDW-SD, RDW-CV, PDW*, MPV, PCT P-LCR* Research Parameters %. IG# Detection Principles Flow cytometry method using a semiconductor laser (WBC, WBC5DIFF, RET) Hydrodynamic focusing DC detection method (RBC, PLT) SLS-hemoglobin method (HGB) Flow cytometry method using a semiconductor laser (WBC, WBC5DIFF) Hydrodynamic focusing DC detection method (RBC, PLT) SLS-hemoglobin method (HGB) Throughput Up to 80 samples/hour Discrete Testing CBC Mode, CBC + DIFF Mode CBC+DIFF+RETMode CBC+RET Mode CBC Mode, CBC+DIFF Mode Sample Volume Manual Mode : 85 microlitre Manual Closed Mode : 150 microlitre Capillary Mode : 40 microlitre Data Storage Analysis data : Up to 10,000 with histograms and scatter grams Patient Information : Up to 5,000 patients Test Order Information : Up to 1,000 orders Quality Control Files: 21 files, each with 300 data points. |